FAQ

Do you provide both level counting and single space counting solutions?
Yes, our company offers both technologies. Also, ParkSonic is the only company capable of providing indoor and outdoor parking solutions. 
Fri, 26 Jan, 2018 at 12:45 PM
Do you have operating installations of your system in North America?
We have 22 projects installed in the United States totaling approximately 29,000 parking spaces in (5) States. In New, York, Ohio, Texas, Nevada and Califor...
Fri, 26 Jan, 2018 at 12:46 PM
How many years has your firm been offering an PGS solution?
ParkSonic as distributor has been offering PGS in US for the past 3 years and our partner ParkHelp has more than 14 years of experience with this technology....
Fri, 26 Jan, 2018 at 12:47 PM
What type of sensor(s) do you offer for both level counting and single space counting?
Our system works with ultrasonic sensors for indoor PGS system, and ultra-magnetic for our outdoor system.
Fri, 26 Jan, 2018 at 12:48 PM
How is your management software set-up - web-based portal, LAN server, other?
Our management software is called ParkManager and it can be set up in tow ways depending on our customer’s needs and budget: (1) local server and (2) web-b...
Fri, 26 Jan, 2018 at 12:49 PM
Would you be willing to a pre-meeting with our staff prior to installation to detail the process to provide more detailed solution specific to your system?
Yes. We usually deploy a technician to evaluate every project pre-meeting and prior to installation to update or not any adjustments on the drawings, if ne...
Fri, 26 Jan, 2018 at 12:50 PM
How would you rate your systems accuracy level for a level count in a facility assuming each entry and exit point is channeled over the count point?
Level count is a system that is subject to the driver’s behavior therefore it requires the drivers to pass underneath the sensors. We install our sensors i...
Fri, 26 Jan, 2018 at 12:51 PM
What are the power requirements for each count point? (Volts/AMPS/Number of circuits)
The system is design for 30V/DC. We have in our cabinet’s power supplies to convert 120V/AC to 30V/DC. As for circuits, it depends of how many sensors we h...
Fri, 26 Jan, 2018 at 12:52 PM
What are the data requirements for each count point?
We use Cat5 cable for the sensors and RS- 485 cable between the pass counter sensors.
Fri, 26 Jan, 2018 at 12:53 PM
What on-going maintenance is required for each count point? (Such as cleaning/visual inspection/replacing delineator posts as needed)
To avoid any major issues, we recommend a weekly monitoring of the system (remotely) with a quarterly visit from our technician to fix and troubleshoot any...
Fri, 26 Jan, 2018 at 12:54 PM